8 resultados para FTIR-spektroskopia

em CentAUR: Central Archive University of Reading - UK


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The sources of ordinate error in FTIR spectrometers are reviewed with reference to measuring small out-of-band features in the spectra of bandpass filters. Procedures for identifying instrumental artefacts are described. It is shown that features well below 0.01%T can be measured reliably.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The vibrational structure of C---H stretching states in gas-phase cyclobutene was studied using FTIR spectroscopy in the range 700–9000 cm−1. The structure was modelled using two effective vibrational Hamiltonians, one for each type of C---H bond present, consisting of local mode basis functions subject to coupling with symmetrically equivalent bonds and to Fermi resonances with suitable low frequency vibrations. Best-fit model parameters were determined using least-squares routines and the model predictions are compared to the observed band positions and intensities. Some discussion is given of the relevance of the observed couplings to intramolecular vibrational redistribution (IVR) which results in the observation of statistical behaviour in cyclobutene isomerization induced by excitation of C---H stretching overtones in the visible region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The polymer conformation structure of gluten extracted from a Polish wheat cultivar, Korweta, and gluten subtractions obtained from 2 U.K. breadmaking and biscuit flour cultivars, Hereward and Riband, was investigated using attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR). The results showed the conformation of proteins varied between flour, hydrated flour, and hydrated gluten. The beta-sheet structure increased progressively from flour to hydrated flour and to hydrated gluten. In hydrated gluten protein fractions comprising gliadin, soluble glutenin, and gel protein, beta-sheet structure increased progressively from soluble gliadin and glutenin to gluten and gel protein; beta-sheet content was also greater in the gel protein from the breadmaking flour Hereward than the biscuit flour Riband.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports on the design and manufacture of an ultra-wide (5-30µm) infrared edge filter for use in FTIR studies of the low frequency vibrational modes of metallo-proteins. We present details of the spectral design and manufacture of such a filter which meets the demanding bandwidth and transparency requirements of the application, and spectra that present the new data possible with such a filter. A design model of the filter and the materials used in its construction has been developed capable of accurately predicting spectral performance at both 300K and at the reduced operating temperature at 200K. This design model is based on the optical and semiconductor properties of a multilayer filter containing PbTe (IV-VI) layer material in combination with the dielectric dispersion of ZnSe (II-VI) deposited on a CdTe (II-VI) substrate together with the use of BaF2 (II-VII) as an antireflection layer. Comparisons between the computed spectral performance of the model and spectral measurements from manufactured coatings over a wavelength range of 4-30µm and temperature range 300-200K are presented. Finally we present the results of the FTIR measurements of Photosystem II showing the improvement in signal to noise ratio of the measurement due to using the filter, together with a light induced FTIR difference spectrum of Photosystem II.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the first time, vertical column measurements of (HNO3) above the Arctic Stratospheric Ozone Observatory (AStrO) at Eureka (80N, 86W), Canada, have been made during polar night using lunar spectra recorded with a Fourier Transform Infrared (FTIR) spectrometer, from October 2001 to March 2002. AStrO is part of the primary Arctic station of the Network for the Detection of Stratospheric Change (NDSC). These measurements were compared with FTIR measurements at two other NDSC Arctic sites: Thule, Greenland (76.5N, 68.8W) and Kiruna, Sweden (67.8N, 20.4E). The measurements were also compared with two atmospheric models: the Canadian Middle Atmosphere Model (CMAM) and SLIMCAT. This is the first time that CMAM HNO3 columns have been compared with observations in the Arctic. Eureka lunar measurements are in good agreement with solar ones made with the same instrument. Eureka and Thule HNO3 columns are consistent within measurement error. Differences among HNO3 columns measured at Kiruna and those measured at Eureka and Thule can be explained on the basis of the available sunlight hours and the polar vortex location. The comparison of CMAM HNO3 columns with Eureka and Kiruna data shows good agreement, considering CMAM small inter-annual variability. The warm 2001/02 winter with almost no Polar Stratospheric Clouds (PSCs) makes the comparison of the warm climate version of CMAM with these observations a good test for CMAM under no PSC conditions. SLIMCAT captures the magnitude of HNO3 columns at Eureka, and the day-to-day variability, but generally reports higher HNO3 columns than the CMAM climatological mean columns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The self-assembly of proteins and peptides into b-sheet-rich amyloid fibers is a process that has gained notoriety because of its association with human diseases and disorders. Spontaneous self-assembly of peptides into nonfibrillar supramolecular structures can also provide a versatile and convenient mechanism for the bottom-up design of biocompatible materials with functional properties favoring a wide range of practical applications.[1] One subset of these fascinating and potentially useful nanoscale constructions are the peptide nanotubes, elongated cylindrical structures with a hollow center bounded by a thin wall of peptide molecules.[2] A formidable challenge in optimizing and harnessing the properties of nanotube assemblies is to gain atomistic insight into their architecture, and to elucidate precisely how the tubular morphology is constructed from the peptide building blocks. Some of these fine details have been elucidated recently with the use of magic-angle-spinning (MAS) solidstate NMR (SSNMR) spectroscopy.[3] MAS SSNMR measurements of chemical shifts and through-space interatomic distances provide constraints on peptide conformation (e.g., b-strands and turns) and quaternary packing. We describe here a new application of a straightforward SSNMR technique which, when combined with FTIR spectroscopy, reports quantitatively on the orientation of the peptide molecules within the nanotube structure, thereby providing an additional structural constraint not accessible to MAS SSNMR.